Journal Information
Vol. 26. Issue 5.
Pages 181-185 (June - July 1990)
Share
Share
Download PDF
More article options
Vol. 26. Issue 5.
Pages 181-185 (June - July 1990)
Full text access
Variaciones de la gasometría arterial en relación con la manipulación de la muestra y material empleado
Variations of arterial blood gases in relation with manipulation of the sample and with the used material
Visits
4024
J.L. Izquierdo, M.S. Ribas, M. Izquierdo, J.M. Rodríguez, J.L. Viejo
Sección de Neumología. Hospital General Yagüe. Burgos
This item has received
Article information
Abstract
Bibliography
Download PDF
Statistics

Con la finalidad de determinar posibles variaciones en la gasometría arterial (GA) dependiendo del método de conservación y del material de jeringa utilizado, se analizaron las muestras procedentes de 23 pacientes respirando aire ambiente y de 20 enfermos con insuficiencia respiratoria crónica (IRC) recibiendo oxígeno suplementario al 24-28%. De cada enfermo se obtuvieron 6 muestras que se mantuvieron en jeringas de cristal y plástico, tanto a temperatura ambiente como en hielo. La duración de cada estudio fue de 2 horas, realizándose una lectura basal y posteriormente a los 15, 30, 60 y 120 minutos.

Sólo cuando la muestra se mantuvo en jeringa de cristal y hielo, los resultados fueron adecuados a las dos horas postextracción. En el resto, una demora en la lectura superior a 15 minutos produjo variaciones en la PaO2, PaCO2 y pH, que fueron incrementándose de forma progresiva en función del tiempo transcurrido.

Es de resaltar la magnitud de los cambios observados, con diferencias al final del estudio de 9,4 y 10 mmHg en la PaO2 de los dos grupos, diferencias que por sí mismas pueden condicionar importantes cambios en el diagnóstico y manejo clínico, especialmente del paciente con IRC.

To determine possible variations in the values of arterial blood gases depending on the preservation procedure and on the characteristics of the syringe used, the samples obtained in 23 patients breathing ambiental air and in 20 patients with chronic respiratory failure receiving oxygen at 24 to 28%, were analyzed. In each patient 6 samples were obtained and were collected with crystal or plastic syringes at room temperature and under ice. The duration of the study was about 2 hours. Samples were analyzed at baseline and after 15,30,60, and 120 min. Samples collected with crystal syringes and those kept under ice gave the more concordant values during the two hours that followed the extraction. In the remaining situations a delay of 15 min after extraction produced variations in the values of PaO2, PaCO2, and pH. These variations increased with the time. At the late stages of the study, differences of 9.4 to 10 mmHg in PaO2 could be seen. This variability may be of clinical relevance in the diagnosis and treatment specially in patients with chronic respiratory failure.

Full text is only aviable in PDF
Bibliografía
[1.]
T.A. Raffin.
Indications for arterial blood gas analysis.
Ann Intern Med, 105 (1986), pp. 390-398
[2.]
W. Evers, et al.
A comparative study of plastic (polypropylene) and glass syringes in blood-gas analysis.
Anesth-Analg, 51 (1972), pp. 92-97
[3.]
G. Fletcher, L.B. Jergen.
Effect of sampling technique on the determination of PaO2 during oxygen breathing.
J Appl Physiol, 21 (1966), pp. 463-468
[4.]
J. Abramson, et al.
Blood gas stability in terumo plastic and glass syringes.
Resp Care, 23 (1978), pp. 63-64
[5.]
B.A. Shapiro, et al.
Manejo clínico de los gases sanguíneos.
Editorial Médica Panamericana, (1979), pp. 156
[6.]
A.M. Vaida, et al.
Controle de qualité de la measure des pressions partielles d’oxygéne et de gaz carbonique dans le sang.
Bull Europ Physiopathol Resp, 16 (1980), pp. 67-78
[7.]
M.B. Laver, A. Seifen.
Measurement of blood oxygen tension in anesthesiology.
Anesthesiology, 26 (1965), pp. 73-101
[8.]
D.E. Hansen.
A systematic error in the determination of blood PaCO2.
Am Rev Respir Dis, 115 (1977), pp. 1.061-1.062
[9.]
Normativa sobre gasometría arterial. Recomendaciones SEPAR.
Ed Doyma, (1987),
Copyright © 1990. Sociedad Española de Neumología y Cirugía Torácica
Archivos de Bronconeumología
Article options
Tools

Are you a health professional able to prescribe or dispense drugs?