array:22 [ "pii" => "S0300289602752654" "issn" => "03002896" "doi" => "10.1016/S0300-2896(02)75265-4" "estado" => "S300" "fechaPublicacion" => "2002-10-01" "aid" => "75265" "copyright" => "Sociedad Española de Neumología y Cirugía Torácica" "copyrightAnyo" => "2002" "documento" => "article" "crossmark" => 0 "subdocumento" => "edi" "cita" => "Arch Bronconeumol. 2002;38:461-2" "abierto" => array:3 [ "ES" => true "ES2" => true "LATM" => true ] "gratuito" => true "lecturas" => array:2 [ "total" => 6642 "formatos" => array:3 [ "EPUB" => 49 "HTML" => 5772 "PDF" => 821 ] ] "itemSiguiente" => array:18 [ "pii" => "S0300289602752666" "issn" => "03002896" "doi" => "10.1016/S0300-2896(02)75266-6" "estado" => "S300" "fechaPublicacion" => "2002-10-01" "aid" => "75266" "copyright" => "Sociedad Española de Neumología y Cirugía Torácica" "documento" => "article" "crossmark" => 0 "subdocumento" => "fla" "cita" => "Arch Bronconeumol. 2002;38:463-7" "abierto" => array:3 [ "ES" => true "ES2" => true "LATM" => true ] "gratuito" => true "lecturas" => array:2 [ "total" => 7888 "formatos" => array:3 [ "EPUB" => 72 "HTML" => 6885 "PDF" => 931 ] ] "es" => array:10 [ "idiomaDefecto" => true "titulo" => "Utilización de la CPAP de forma no invasiva en la laringitis postextubación del paciente pediátrico. Estudio controlado y aleatorizado" "tienePdf" => "es" "tieneTextoCompleto" => 0 "tieneResumen" => array:2 [ 0 => "es" 1 => "en" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "463" "paginaFinal" => "467" ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Non-invasive continuous positive airways pressure for laryngitis postextubation in pediatric patients" ] ] "contieneResumen" => array:2 [ "es" => true "en" => true ] "contienePdf" => array:1 [ "es" => true ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "J.A. Rodríguez, B. Von Dessauer, G. Duffau" "autores" => array:3 [ 0 => array:2 [ "nombre" => "J.A." "apellidos" => "Rodríguez" ] 1 => array:2 [ "nombre" => "B." "apellidos" => "Von Dessauer" ] 2 => array:2 [ "nombre" => "G." "apellidos" => "Duffau" ] ] ] ] ] "idiomaDefecto" => "es" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0300289602752666?idApp=UINPBA00003Z" "url" => "/03002896/0000003800000010/v1_201307081551/S0300289602752666/v1_201307081551/es/main.assets" ] "es" => array:10 [ "idiomaDefecto" => true "titulo" => "Nuevas aplicaciones de la resonancia magnética en el tórax" "tieneTextoCompleto" => 0 "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "461" "paginaFinal" => "462" ] ] "autores" => array:1 [ 0 => array:4 [ "autoresLista" => "G. Peces-Barba" "autores" => array:1 [ 0 => array:4 [ "nombre" => "G." "apellidos" => "Peces-Barba" "email" => array:1 [ 0 => "gpecesba@fjd.es" ] "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">¿</span>" "identificador" => "cor0005" ] ] ] ] "afiliaciones" => array:1 [ 0 => array:1 [ "entidad" => "Servicio de Neumología. Fundación Jiménez Díaz. Madrid" ] ] "correspondencia" => array:1 [ 0 => array:3 [ "identificador" => "cor0005" "etiqueta" => "⁎" "correspondencia" => "Correspondencia: Avda. Reyes Católicos, 2. 28040 Madrid" ] ] ] ] "pdfFichero" => "main.pdf" "tienePdf" => true "fechaRecibido" => "2002-06-03" "fechaAceptado" => "2002-06-18" "bibliografia" => array:2 [ "titulo" => "Bibliografía" "seccion" => array:1 [ 0 => array:2 [ "identificador" => "bibs0005" "bibliografiaReferencia" => array:21 [ 0 => array:3 [ "identificador" => "bib0005" "etiqueta" => "1." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Magnetic resonance approaches to the evaluation of pulmonary vascular anatomy and physiology" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "H. Hatabu" 1 => "W.B. Gefter" 2 => "J. Konishi" 3 => "H.Y. Kressel" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Magn Reson Q" "fecha" => "1991" "volumen" => "7" "paginaInicial" => "208" "paginaFinal" => "225" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/1747332" "web" => "Medline" ] ] ] ] ] ] ] ] 1 => array:3 [ "identificador" => "bib0010" "etiqueta" => "2." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Improved visualization of the human lung in 1H MRI using multiple inversion recovery for simultaneous suppression of signal contributions from fat and muscle" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "V.M. Mai" 1 => "J. Knight-Scott" 2 => "S.S. Berr" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Magn Reson Med" "fecha" => "1999" "volumen" => "41" "paginaInicial" => "866" "paginaFinal" => "870" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/10332866" "web" => "Medline" ] ] ] ] ] ] ] ] 2 => array:3 [ "identificador" => "bib0015" "etiqueta" => "3." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "MR imaging with spatial modulation of magnetization in the evaluation of chronic central pulmonary thromboemboli" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "H. Hatabu" 1 => "W.B. Gefter" 2 => "L. Axel" 3 => "H.I. Palevsky" 4 => "C. Cope" 5 => "N. Reichek" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1148/radiology.190.3.8115629" "Revista" => array:6 [ "tituloSerie" => "Radiology" "fecha" => "1994" "volumen" => "190" "paginaInicial" => "791" "paginaFinal" => "796" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/8115629" "web" => "Medline" ] ] ] ] ] ] ] ] 3 => array:3 [ "identificador" => "bib0020" "etiqueta" => "4." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Pulmonary MR angiography utilizing phasedarray surface coils" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "H. Hatabu" 1 => "W.B. Gefter" 2 => "J. Listerud" 3 => "E.A. Hoffman" 4 => "L. Axel" 5 => "McGowan JC 3.r.d." ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "J Comput Assist Tomogr" "fecha" => "1992" "volumen" => "16" "paginaInicial" => "410" "paginaFinal" => "417" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/1592923" "web" => "Medline" ] ] ] ] ] ] ] ] 4 => array:3 [ "identificador" => "bib0025" "etiqueta" => "5." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "MR perfusion imaging using encapsulated laser-polarized 3He" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:8 [ 0 => "V. Callot" 1 => "E. Canet" 2 => "J. Brochot" 3 => "M. Viallon" 4 => "H. Humblot" 5 => "A. Briguet" 6 => "H. Tournier" 7 => "Y. Cremillieux" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Magn Reson Med." "fecha" => "2001" "volumen" => "46" "paginaInicial" => "535" "paginaFinal" => "540" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/11550246" "web" => "Medline" ] ] ] ] ] ] ] ] 5 => array:3 [ "identificador" => "bib0030" "etiqueta" => "6." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Diagnosis of pulmonary embolism with magnetic resonance angiography" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "J.F. Meaney" 1 => "J.G. Weg" 2 => "T.L. Chenevert" 3 => "D. Stafford-Johnson" 4 => "B.H. Hamilton" 5 => "M.R. Prince" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1056/NEJM199705153362004" "Revista" => array:6 [ "tituloSerie" => "N Engl J Med" "fecha" => "1997" "volumen" => "336" "paginaInicial" => "1422" "paginaFinal" => "1427" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/9145679" "web" => "Medline" ] ] ] ] ] ] ] ] 6 => array:3 [ "identificador" => "bib0035" "etiqueta" => "7." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Magnetic resonance imaging of pulmonary ventilation. Initial experiences with a gadolinium-DTPA-based aerosol" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "B. Misselwitz" 1 => "A. Muhler" 2 => "I. Heinzelmann" 3 => "J.C. Bock" 4 => "H.J. Weinmann" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Invest Radiol" "fecha" => "1997" "volumen" => "32" "paginaInicial" => "797" "paginaFinal" => "801" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/9406020" "web" => "Medline" ] ] ] ] ] ] ] ] 7 => array:3 [ "identificador" => "bib0040" "etiqueta" => "8." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Pulmonary ventilation imaged by magnetic resonance: at the doorstep of clinical application" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "H.U. Kauczor" 1 => "X.J. Chen" 2 => "E.J. Van Beek" 3 => "W.G. Schreiber" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Eur Respir J" "fecha" => "2001" "volumen" => "17" "paginaInicial" => "1008" "paginaFinal" => "1023" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/11488304" "web" => "Medline" ] ] ] ] ] ] ] ] 8 => array:3 [ "identificador" => "bib0045" "etiqueta" => "9." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Multiple inversion recovery MR subtraction imaging of human ventilation from inhalation of room air and pure oxygen" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "V.M. Mai" 1 => "Q. Chen" 2 => "A.A. Bankier" 3 => "R.R. Edelman" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Magn Reson Med" "fecha" => "2000" "volumen" => "43" "paginaInicial" => "913" "paginaFinal" => "916" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/10861890" "web" => "Medline" ] ] ] ] ] ] ] ] 9 => array:3 [ "identificador" => "bib0050" "etiqueta" => "10." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Mixing oxygen with hyperpolarized 3He for small-animal lung studies" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "L.W. Hedlund" 1 => "H.E. Moller" 2 => "X.J. Chen" 3 => "M.S. Chawla" 4 => "G.P. Cofer" 5 => "G.A. Johnson" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "NMR Biomed" "fecha" => "2000" "volumen" => "13" "paginaInicial" => "202" "paginaFinal" => "206" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/10867697" "web" => "Medline" ] ] ] ] ] ] ] ] 10 => array:3 [ "identificador" => "bib0055" "etiqueta" => "11." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "3He-MRI-based measurements of intrapulmonary pO2 and its time course during apnea in healthy volunteers: first results, reproducibility, and technical limitations" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "A.J. Deninger" 1 => "B. Eberle" 2 => "M. Ebert" 3 => "T. Grossmann" 4 => "G. Hanisch" 5 => "W. Heil" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "NMR Biomed" "fecha" => "2000" "volumen" => "13" "paginaInicial" => "194" "paginaFinal" => "201" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/10867696" "web" => "Medline" ] ] ] ] ] ] ] ] 11 => array:3 [ "identificador" => "bib0060" "etiqueta" => "12." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Functional MR microscopy of the lung using hyperpolarized 3He" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "M. Viallon" 1 => "G.P. Cofer" 2 => "S.A. Suddarth" 3 => "H.E. Moller" 4 => "X.J. Chen" 5 => "M.S. Chawla" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Magn Reson Med" "fecha" => "1999" "volumen" => "41" "paginaInicial" => "787" "paginaFinal" => "792" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/10332855" "web" => "Medline" ] ] ] ] ] ] ] ] 12 => array:3 [ "identificador" => "bib0065" "etiqueta" => "13." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Effect on single breath washout and lung function of elastase induced emphysema in rats" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "N. González-Mangado" 1 => "G. Peces-Barba" 2 => "J.J. Cabanillas" 3 => "G. Renedo" 4 => "S. Verbänck" 5 => "M. Paiva" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Am J Respir Crit Care Med" "fecha" => "1993" "volumen" => "148" "paginaInicial" => "975" "paginaFinal" => "981" ] ] ] ] ] ] 13 => array:3 [ "identificador" => "bib0070" "etiqueta" => "14." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Intrapulmonary gas mixing in panacinar- and centriacinar-induced emphysema in rats" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "M.L. Rubio" 1 => "M.V. Sánchez-Cifuentes" 2 => "G. Peces-Barba" 3 => "S. Verbanck" 4 => "M. Paiva" 5 => "N. González Mangado" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1164/ajrccm.157.1.9704038" "Revista" => array:6 [ "tituloSerie" => "Am J Respir Crit Care Med" "fecha" => "1998" "volumen" => "157" "paginaInicial" => "237" "paginaFinal" => "245" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/9445305" "web" => "Medline" ] ] ] ] ] ] ] ] 14 => array:3 [ "identificador" => "bib0075" "etiqueta" => "15." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Spatially resolved measurements of hyperpolarized gas properties in the lung in vivo. Part I: diffusion coefficient" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:7 [ 0 => "X.J. Chen" 1 => "H.E. Möller" 2 => "M.S. Chawla" 3 => "G.P. Cofer" 4 => "B. Driehuys" 5 => "L.W. Hedlund" 6 => "G.A. Johnson" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Magn Reson Med" "fecha" => "1999" "volumen" => "42" "paginaInicial" => "721" "paginaFinal" => "728" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/10502761" "web" => "Medline" ] ] ] ] ] ] ] ] 15 => array:3 [ "identificador" => "bib0080" "etiqueta" => "16." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Detection of emphysema in rat lungs by using magnetic resonance measurements of 3He diffusion" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "X.J. Chen" 1 => "L.W. Hedlund" 2 => "H.E. Möller" 3 => "M.S. Chawla" 4 => "R.R. Maronpot" 5 => "G.A. Johnson" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1073/pnas.97.21.11478" "Revista" => array:6 [ "tituloSerie" => "Proc Natl Acad Sci USA" "fecha" => "2000" "volumen" => "97" "paginaInicial" => "11478" "paginaFinal" => "11481" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/11027348" "web" => "Medline" ] ] ] ] ] ] ] ] 16 => array:3 [ "identificador" => "bib0085" "etiqueta" => "17." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Magnetic resonance imaging with hyperpolarized helium-3 in evaluation of lung emphysema in rat models" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "G. Peces-Barba" 1 => "J. Ruiz-Cabello" 2 => "J. Cremillieux" 3 => "M. Ortega" 4 => "M.L. Rubio" 5 => "M.C. Martín-Mosquero" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Am J Respir Crit Care Med" "fecha" => "2002" "volumen" => "165" "numero" => "Suppl" "paginaInicial" => "A251" ] ] ] ] ] ] 17 => array:3 [ "identificador" => "bib0090" "etiqueta" => "18." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Emphysema: hyperpolarized helium-3 diffusion MR imaging of the lungs compared with spirometric indexes –initial experience" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "M. Salerno" 1 => "E.E. De Lange" 2 => "T.A. Altes" 3 => "J.D. Truwit" 4 => "J.R. Brookeman" 5 => "J.P. Mugler III" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1148/radiol.2221001834" "Revista" => array:6 [ "tituloSerie" => "Radiology" "fecha" => "2002" "volumen" => "222" "paginaInicial" => "252" "paginaFinal" => "260" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/11756734" "web" => "Medline" ] ] ] ] ] ] ] ] 18 => array:3 [ "identificador" => "bib0095" "etiqueta" => "19." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Hyperpolarized Helium-3 diffusion imaging of the lung[editorial]" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "J.R. Mayo" 1 => "M.E. Hayden" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1148/radiol.2221011633" "Revista" => array:6 [ "tituloSerie" => "Radiology" "fecha" => "2002" "volumen" => "222" "paginaInicial" => "8" "paginaFinal" => "11" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/11756698" "web" => "Medline" ] ] ] ] ] ] ] ] 19 => array:3 [ "identificador" => "bib0100" "etiqueta" => "20." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Evaluation of airways in obstructive pulmonary disease using high-resolution computed tomography" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "G.G. King" 1 => "N.L. Muller" 2 => "P.D. Pare" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1164/ajrccm.159.3.9805064" "Revista" => array:6 [ "tituloSerie" => "Am J Respir Crit Care Med" "fecha" => "1999" "volumen" => "159" "paginaInicial" => "992" "paginaFinal" => "1004" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/10051284" "web" => "Medline" ] ] ] ] ] ] ] ] 20 => array:3 [ "identificador" => "bib0105" "etiqueta" => "21." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Sliding thin slab, minimum intensity projection technique in the diagnosis of emphysema: histopathologic-CT correlation" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "M. Remy-Jardin" 1 => "J. Remy" 2 => "B. Gosselin" 3 => "M.C. Copin" 4 => "A. Wurtz" 5 => "A. Duhamel" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1148/radiology.200.3.8756912" "Revista" => array:6 [ "tituloSerie" => "Radiology" "fecha" => "1996" "volumen" => "200" "paginaInicial" => "665" "paginaFinal" => "671" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/8756912" "web" => "Medline" ] ] ] ] ] ] ] ] ] ] ] ] ] "idiomaDefecto" => "es" "url" => "/03002896/0000003800000010/v1_201307081551/S0300289602752654/v1_201307081551/es/main.assets" "Apartado" => array:4 [ "identificador" => "14517" "tipo" => "SECCION" "es" => array:2 [ "titulo" => "Editorials / Editoriales" "idiomaDefecto" => true ] "idiomaDefecto" => "es" ] "PDF" => "https://static.elsevier.es/multimedia/03002896/0000003800000010/v1_201307081551/S0300289602752654/v1_201307081551/es/main.pdf?idApp=UINPBA00003Z&text.app=https://archbronconeumol.org/" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0300289602752654?idApp=UINPBA00003Z" ]
Journal Information
Vol. 38. Issue 10.
Pages 461-462 (October 2002)
Vol. 38. Issue 10.
Pages 461-462 (October 2002)
Full text access
Nuevas aplicaciones de la resonancia magnética en el tórax
Visits
9465
G. Peces-Barba
Corresponding author
Servicio de Neumología. Fundación Jiménez Díaz. Madrid
This item has received
Article information
Full text is only aviable in PDF
Bibliografía
[1.]
H. Hatabu, W.B. Gefter, J. Konishi, H.Y. Kressel.
Magnetic resonance approaches to the evaluation of pulmonary vascular anatomy and physiology.
Magn Reson Q, 7 (1991), pp. 208-225
[2.]
V.M. Mai, J. Knight-Scott, S.S. Berr.
Improved visualization of the human lung in 1H MRI using multiple inversion recovery for simultaneous suppression of signal contributions from fat and muscle.
Magn Reson Med, 41 (1999), pp. 866-870
[3.]
H. Hatabu, W.B. Gefter, L. Axel, H.I. Palevsky, C. Cope, N. Reichek, et al.
MR imaging with spatial modulation of magnetization in the evaluation of chronic central pulmonary thromboemboli.
Radiology, 190 (1994), pp. 791-796
[4.]
H. Hatabu, W.B. Gefter, J. Listerud, E.A. Hoffman, L. Axel, McGowan JC 3.r.d., et al.
Pulmonary MR angiography utilizing phasedarray surface coils.
J Comput Assist Tomogr, 16 (1992), pp. 410-417
[5.]
V. Callot, E. Canet, J. Brochot, M. Viallon, H. Humblot, A. Briguet, H. Tournier, Y. Cremillieux.
MR perfusion imaging using encapsulated laser-polarized 3He.
Magn Reson Med., 46 (2001), pp. 535-540
[6.]
J.F. Meaney, J.G. Weg, T.L. Chenevert, D. Stafford-Johnson, B.H. Hamilton, M.R. Prince.
Diagnosis of pulmonary embolism with magnetic resonance angiography.
N Engl J Med, 336 (1997), pp. 1422-1427
[7.]
B. Misselwitz, A. Muhler, I. Heinzelmann, J.C. Bock, H.J. Weinmann.
Magnetic resonance imaging of pulmonary ventilation. Initial experiences with a gadolinium-DTPA-based aerosol.
Invest Radiol, 32 (1997), pp. 797-801
[8.]
H.U. Kauczor, X.J. Chen, E.J. Van Beek, W.G. Schreiber.
Pulmonary ventilation imaged by magnetic resonance: at the doorstep of clinical application.
Eur Respir J, 17 (2001), pp. 1008-1023
[9.]
V.M. Mai, Q. Chen, A.A. Bankier, R.R. Edelman.
Multiple inversion recovery MR subtraction imaging of human ventilation from inhalation of room air and pure oxygen.
Magn Reson Med, 43 (2000), pp. 913-916
[10.]
L.W. Hedlund, H.E. Moller, X.J. Chen, M.S. Chawla, G.P. Cofer, G.A. Johnson.
Mixing oxygen with hyperpolarized 3He for small-animal lung studies.
NMR Biomed, 13 (2000), pp. 202-206
[11.]
A.J. Deninger, B. Eberle, M. Ebert, T. Grossmann, G. Hanisch, W. Heil, et al.
3He-MRI-based measurements of intrapulmonary pO2 and its time course during apnea in healthy volunteers: first results, reproducibility, and technical limitations.
NMR Biomed, 13 (2000), pp. 194-201
[12.]
M. Viallon, G.P. Cofer, S.A. Suddarth, H.E. Moller, X.J. Chen, M.S. Chawla, et al.
Functional MR microscopy of the lung using hyperpolarized 3He.
Magn Reson Med, 41 (1999), pp. 787-792
[13.]
N. González-Mangado, G. Peces-Barba, J.J. Cabanillas, G. Renedo, S. Verbänck, M. Paiva.
Effect on single breath washout and lung function of elastase induced emphysema in rats.
Am J Respir Crit Care Med, 148 (1993), pp. 975-981
[14.]
M.L. Rubio, M.V. Sánchez-Cifuentes, G. Peces-Barba, S. Verbanck, M. Paiva, N. González Mangado.
Intrapulmonary gas mixing in panacinar- and centriacinar-induced emphysema in rats.
Am J Respir Crit Care Med, 157 (1998), pp. 237-245
[15.]
X.J. Chen, H.E. Möller, M.S. Chawla, G.P. Cofer, B. Driehuys, L.W. Hedlund, G.A. Johnson.
Spatially resolved measurements of hyperpolarized gas properties in the lung in vivo. Part I: diffusion coefficient.
Magn Reson Med, 42 (1999), pp. 721-728
[16.]
X.J. Chen, L.W. Hedlund, H.E. Möller, M.S. Chawla, R.R. Maronpot, G.A. Johnson.
Detection of emphysema in rat lungs by using magnetic resonance measurements of 3He diffusion.
Proc Natl Acad Sci USA, 97 (2000), pp. 11478-11481
[17.]
G. Peces-Barba, J. Ruiz-Cabello, J. Cremillieux, M. Ortega, M.L. Rubio, M.C. Martín-Mosquero, et al.
Magnetic resonance imaging with hyperpolarized helium-3 in evaluation of lung emphysema in rat models.
Am J Respir Crit Care Med, 165 (2002), pp. A251
[18.]
M. Salerno, E.E. De Lange, T.A. Altes, J.D. Truwit, J.R. Brookeman, J.P. Mugler III.
Emphysema: hyperpolarized helium-3 diffusion MR imaging of the lungs compared with spirometric indexes –initial experience.
Radiology, 222 (2002), pp. 252-260
[19.]
J.R. Mayo, M.E. Hayden.
Hyperpolarized Helium-3 diffusion imaging of the lung[editorial].
Radiology, 222 (2002), pp. 8-11
[20.]
G.G. King, N.L. Muller, P.D. Pare.
Evaluation of airways in obstructive pulmonary disease using high-resolution computed tomography.
Am J Respir Crit Care Med, 159 (1999), pp. 992-1004
[21.]
M. Remy-Jardin, J. Remy, B. Gosselin, M.C. Copin, A. Wurtz, A. Duhamel.
Sliding thin slab, minimum intensity projection technique in the diagnosis of emphysema: histopathologic-CT correlation.
Radiology, 200 (1996), pp. 665-671
Copyright © 2002. Sociedad Española de Neumología y Cirugía Torácica