array:23 [
  "pii" => "S030028961532706X"
  "issn" => "03002896"
  "doi" => "10.1016/S0300-2896(15)32706-X"
  "estado" => "S300"
  "fechaPublicacion" => "1977-01-01"
  "aid" => "72775"
  "copyright" => "Sociedad Española de Neumología y Cirugía Torácica"
  "copyrightAnyo" => "1977"
  "documento" => "article"
  "crossmark" => 0
  "subdocumento" => "fla"
  "cita" => "Arch Bronconeumol. 1977;13:56-61"
  "abierto" => array:3 [
    "ES" => true
    "ES2" => true
    "LATM" => true
  ]
  "gratuito" => true
  "lecturas" => array:2 [
    "total" => 1512
    "formatos" => array:3 [
      "EPUB" => 45
      "HTML" => 824
      "PDF" => 643
    ]
  ]
  "itemSiguiente" => array:18 [
    "pii" => "S0300289615327071"
    "issn" => "03002896"
    "doi" => "10.1016/S0300-2896(15)32707-1"
    "estado" => "S300"
    "fechaPublicacion" => "1977-01-01"
    "aid" => "72776"
    "copyright" => "Sociedad Española de Neumología y Cirugía Torácica"
    "documento" => "article"
    "crossmark" => 0
    "subdocumento" => "fla"
    "cita" => "Arch Bronconeumol. 1977;13:62-8"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 1895
      "formatos" => array:3 [
        "EPUB" => 45
        "HTML" => 799
        "PDF" => 1051
      ]
    ]
    "es" => array:10 [
      "idiomaDefecto" => true
      "titulo" => "Bases farmacologicas de la medicacion beta-2-adrenergica"
      "tienePdf" => "es"
      "tieneTextoCompleto" => 0
      "tieneResumen" => array:2 [
        0 => "es"
        1 => "en"
      ]
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "62"
          "paginaFinal" => "68"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "en" => array:1 [
          "titulo" => "Pharmacological bases of the medication beta-2-adrenergic"
        ]
      ]
      "contieneResumen" => array:2 [
        "es" => true
        "en" => true
      ]
      "contienePdf" => array:1 [
        "es" => true
      ]
      "autores" => array:2 [
        0 => array:2 [
          "autoresLista" => "R. Tallón Moreno, J.J. Fernández García, J.A. Durán Quintana, R. Tallon Cantero"
          "autores" => array:4 [
            0 => array:2 [
              "nombre" => "R."
              "apellidos" => "Tallón Moreno"
            ]
            1 => array:2 [
              "nombre" => "J.J."
              "apellidos" => "Fernández García"
            ]
            2 => array:2 [
              "nombre" => "J.A."
              "apellidos" => "Durán Quintana"
            ]
            3 => array:2 [
              "nombre" => "R."
              "apellidos" => "Tallon Cantero"
            ]
          ]
        ]
        1 => array:2 [
          "autoresLista" => "G. Sánchez de la Cuesta"
          "autores" => array:1 [
            0 => array:2 [
              "nombre" => "G."
              "apellidos" => "Sánchez de la Cuesta"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "es"
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0300289615327071?idApp=UINPBA00003Z"
    "url" => "/03002896/0000001300000001/v1_201509151304/S0300289615327071/v1_201509151304/es/main.assets"
  ]
  "itemAnterior" => array:18 [
    "pii" => "S0300289615327058"
    "issn" => "03002896"
    "doi" => "10.1016/S0300-2896(15)32705-8"
    "estado" => "S300"
    "fechaPublicacion" => "1977-01-01"
    "aid" => "72774"
    "copyright" => "Sociedad Española de Neumología y Cirugía Torácica"
    "documento" => "article"
    "crossmark" => 0
    "subdocumento" => "fla"
    "cita" => "Arch Bronconeumol. 1977;13:48-55"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 1756
      "formatos" => array:3 [
        "EPUB" => 62
        "HTML" => 758
        "PDF" => 936
      ]
    ]
    "es" => array:10 [
      "idiomaDefecto" => true
      "titulo" => "Complicaciones en cirugia torácica"
      "tienePdf" => "es"
      "tieneTextoCompleto" => 0
      "tieneResumen" => array:2 [
        0 => "es"
        1 => "en"
      ]
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "48"
          "paginaFinal" => "55"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "en" => array:1 [
          "titulo" => "Complications in thoracic surgery"
        ]
      ]
      "contieneResumen" => array:2 [
        "es" => true
        "en" => true
      ]
      "contienePdf" => array:1 [
        "es" => true
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "F. Serrano Muñoz"
          "autores" => array:1 [
            0 => array:2 [
              "nombre" => "F."
              "apellidos" => "Serrano Muñoz"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "es"
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0300289615327058?idApp=UINPBA00003Z"
    "url" => "/03002896/0000001300000001/v1_201509151304/S0300289615327058/v1_201509151304/es/main.assets"
  ]
  "es" => array:12 [
    "idiomaDefecto" => true
    "titulo" => "La mucoelastografia"
    "tieneTextoCompleto" => 0
    "paginas" => array:1 [
      0 => array:2 [
        "paginaInicial" => "56"
        "paginaFinal" => "61"
      ]
    ]
    "autores" => array:1 [
      0 => array:3 [
        "autoresLista" => "B. Vicens, R. Cornudella, M.A. Fuster, R. Frouchtman"
        "autores" => array:4 [
          0 => array:2 [
            "nombre" => "B."
            "apellidos" => "Vicens"
          ]
          1 => array:2 [
            "nombre" => "R."
            "apellidos" => "Cornudella"
          ]
          2 => array:2 [
            "nombre" => "M.A."
            "apellidos" => "Fuster"
          ]
          3 => array:2 [
            "nombre" => "R."
            "apellidos" => "Frouchtman"
          ]
        ]
        "afiliaciones" => array:2 [
          0 => array:2 [
            "entidad" => "Laboratorio de Automática. Escuela de Ingenieros Industriales de Tarrasa. Universidad Politécnica de Barcelona"
            "identificador" => "aff0005"
          ]
          1 => array:2 [
            "entidad" => "Servicio de Bronconeumología. Hospital de la Santa Cruz y San Pablo. Barcelona"
            "identificador" => "aff0010"
          ]
        ]
      ]
    ]
    "titulosAlternativos" => array:1 [
      "en" => array:1 [
        "titulo" => "Mucoelastography"
      ]
    ]
    "pdfFichero" => "main.pdf"
    "tienePdf" => true
    "tieneResumen" => true
    "resumen" => array:2 [
      "es" => array:2 [
        "titulo" => "Resumen"
        "resumen" => "<span id="abst0005" class="elsevierStyleSection elsevierViewall"><p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">En el presente trabajo&#44; tras un repaso de los fundamentos te&#243;ricos en que se bas&#243; el empleo del Tromboelast&#243;grafo para la determinaci&#243;n de la elasticidad de las secreciones bronquiales&#44; se expone la comprobaci&#243;n del m&#233;todo efectuada mediante la simulaci&#243;n del sistema tromboelast&#243;grafo-secreci&#243;n bronquial mediante un computador anal&#243;gico&#46; Finalmente se discute el inter&#233;s que presenta la morfolog&#237;a del trazado obtenido con el tromboelast&#243;grafo en funci&#243;n de las caracter&#237;sticas rheol&#243;gicas de la muestra que se haya introducido en su cubeta y se apunta el valor que su estudio puede tener en el mejoramiento de la interpretaci&#243;n de los trazados tromboelastogr&#225;ficos&#46;</p></span>"
      ]
      "en" => array:2 [
        "titulo" => "Summary"
        "resumen" => "<span id="abst0010" class="elsevierStyleSection elsevierViewall"><p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">After a review of the theoretical principies on which the use of the thromboelastograph for the determination of the elasticity of bronchial secrections is bases&#44; the auth ors expound on the verification of the method made by the simulation of the thromboelastograph-bronchial secretion system using an analog Computer&#46; Finally the auth ors discuss the interest of the morphology of the tracings obtained with the thromboelastograph in function with the rheologic characteristics of the sample introduced in the test tube&#44; and note the valu&#233; that their study could have in the improvement of the interpretadon of thromboelastograph tracings&#46;</p></span>"
      ]
    ]
    "NotaPie" => array:1 [
      0 => array:2 [
        "etiqueta" => "&#42;"
        "nota" => "<p class="elsevierStyleNotepara" id="np0000">M&#233;todo sencillo y asequible para la determinaci&#243;n de la elasticidad de las secreciones bronquiales&#46;</p>"
      ]
    ]
    "bibliografia" => array:2 [
      "titulo" => "Bibliografia"
      "seccion" => array:1 [
        0 => array:2 [
          "identificador" => "bibs0005"
          "bibliografiaReferencia" => array:6 [
            0 => array:3 [
              "identificador" => "bib0005"
              "etiqueta" => "1&#46;"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Techniques for the measurement of the rheological properties of sputum"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:1 [
                            0 => "S&#46;S&#46; Davis"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:4 [
                        "tituloSerie" => "Bull&#46; Physiopathol&#46; Resp&#46;"
                        "fecha" => "1973"
                        "volumen" => "9"
                        "paginaInicial" => "47"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            1 => array:3 [
              "identificador" => "bib0010"
              "etiqueta" => "2&#46;"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "The rheological properties of sputum"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:2 [
                            0 => "S&#46;S&#46; Davis"
                            1 => "J&#46;E&#46; Dippy"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:4 [
                        "tituloSerie" => "Biorheol&#46;"
                        "fecha" => "1969"
                        "volumen" => "6"
                        "paginaInicial" => "11"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            2 => array:3 [
              "identificador" => "bib0015"
              "etiqueta" => "3&#46;"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Viscoelasficity of mucus Its role in ciliary transport of pulmonary secretions"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:5 [
                            0 => "R&#46; Denton"
                            1 => "W&#46; Forsman"
                            2 => "S&#46;H&#46; Hwang"
                            3 => "M&#46; Litt"
                            4 => "C&#46;E&#46; Miller"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1164/arrd.1968.98.3.380"
                      "Revista" => array:5 [
                        "tituloSerie" => "Am&#46; Rev&#46; Resp&#46; Dis&#46;"
                        "fecha" => "1968"
                        "volumen" => "98"
                        "paginaInicial" => "380"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/5673097"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            3 => array:3 [
              "identificador" => "bib0020"
              "etiqueta" => "4&#46;"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Rheological properties of mucus"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:3 [
                            0 => "S&#46;H&#46; Hwang"
                            1 => "M&#46; Litt"
                            2 => "W&#46;C&#46; Forsman"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:4 [
                        "tituloSerie" => "Rheol&#46; Acta"
                        "fecha" => "1969"
                        "volumen" => "8"
                        "paginaInicial" => "438"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            4 => array:3 [
              "identificador" => "bib0025"
              "etiqueta" => "5&#46;"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Etude sur la mucoelastographie&#44; premiers resultats"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:2 [
                            0 => "B&#46; Vicens"
                            1 => "J&#46; Garcia"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:4 [
                        "tituloSerie" => "Les Bronches"
                        "fecha" => "1971"
                        "volumen" => "12"
                        "paginaInicial" => "372"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            5 => array:3 [
              "identificador" => "bib0030"
              "etiqueta" => "6&#46;"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Etude de l&#8217;action de deux agents mucolytiques&#58; bromhexine et Niacetyl-l-cysteine par la mucoelastographie"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:1 [
                            0 => "B&#46; Vicens"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:4 [
                        "tituloSerie" => "Bull&#46; Physio-pathol&#46; Resp&#46;"
                        "fecha" => "1973"
                        "volumen" => "9"
                        "paginaInicial" => "442"
                      ]
                    ]
                  ]
                ]
              ]
            ]
          ]
        ]
      ]
    ]
  ]
  "idiomaDefecto" => "es"
  "url" => "/03002896/0000001300000001/v1_201509151304/S030028961532706X/v1_201509151304/es/main.assets"
  "Apartado" => array:4 [
    "identificador" => "41253"
    "tipo" => "SECCION"
    "es" => array:2 [
      "titulo" => "Nuevas t&#233;cnicas"
      "idiomaDefecto" => true
    ]
    "idiomaDefecto" => "es"
  ]
  "PDF" => "https://static.elsevier.es/multimedia/03002896/0000001300000001/v1_201509151304/S030028961532706X/v1_201509151304/es/main.pdf?idApp=UINPBA00003Z&text.app=https://archbronconeumol.org/"
  "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S030028961532706X?idApp=UINPBA00003Z"
]
Share
Journal Information
Vol. 13. Issue 1.
Pages 56-61 (January - March 1977)
Share
Share
Download PDF
More article options
Vol. 13. Issue 1.
Pages 56-61 (January - March 1977)
Full text access
La mucoelastografia
Mucoelastography
Visits
3868
B. Vicens, R. Cornudella, M.A. Fuster, R. Frouchtman
Laboratorio de Automática. Escuela de Ingenieros Industriales de Tarrasa. Universidad Politécnica de Barcelona
Servicio de Bronconeumología. Hospital de la Santa Cruz y San Pablo. Barcelona
This item has received
Article information
Abstract
Bibliography
Download PDF
Statistics
Resumen

En el presente trabajo, tras un repaso de los fundamentos teóricos en que se basó el empleo del Tromboelastógrafo para la determinación de la elasticidad de las secreciones bronquiales, se expone la comprobación del método efectuada mediante la simulación del sistema tromboelastógrafo-secreción bronquial mediante un computador analógico. Finalmente se discute el interés que presenta la morfología del trazado obtenido con el tromboelastógrafo en función de las características rheológicas de la muestra que se haya introducido en su cubeta y se apunta el valor que su estudio puede tener en el mejoramiento de la interpretación de los trazados tromboelastográficos.

Summary

After a review of the theoretical principies on which the use of the thromboelastograph for the determination of the elasticity of bronchial secrections is bases, the auth ors expound on the verification of the method made by the simulation of the thromboelastograph-bronchial secretion system using an analog Computer. Finally the auth ors discuss the interest of the morphology of the tracings obtained with the thromboelastograph in function with the rheologic characteristics of the sample introduced in the test tube, and note the valué that their study could have in the improvement of the interpretadon of thromboelastograph tracings.

Full text is only aviable in PDF
Bibliografia
[1.]
S.S. Davis.
Techniques for the measurement of the rheological properties of sputum.
Bull. Physiopathol. Resp., 9 (1973), pp. 47
[2.]
S.S. Davis, J.E. Dippy.
The rheological properties of sputum.
Biorheol., 6 (1969), pp. 11
[3.]
R. Denton, W. Forsman, S.H. Hwang, M. Litt, C.E. Miller.
Viscoelasficity of mucus Its role in ciliary transport of pulmonary secretions.
Am. Rev. Resp. Dis., 98 (1968), pp. 380
[4.]
S.H. Hwang, M. Litt, W.C. Forsman.
Rheological properties of mucus.
Rheol. Acta, 8 (1969), pp. 438
[5.]
B. Vicens, J. Garcia.
Etude sur la mucoelastographie, premiers resultats.
Les Bronches, 12 (1971), pp. 372
[6.]
B. Vicens.
Etude de l’action de deux agents mucolytiques: bromhexine et Niacetyl-l-cysteine par la mucoelastographie.
Bull. Physio-pathol. Resp., 9 (1973), pp. 442

Método sencillo y asequible para la determinación de la elasticidad de las secreciones bronquiales.

Copyright © 1977. Sociedad Española de Neumología y Cirugía Torácica
Archivos de Bronconeumología
Article options
Tools

Are you a health professional able to prescribe or dispense drugs?