Journal Information
Vol. 36. Issue 6.
Pages 319-325 (June 2000)
Share
Share
Download PDF
More article options
Vol. 36. Issue 6.
Pages 319-325 (June 2000)
Full text access
Estudio de cumplimiento del tratamiento por vía inhalatoria en pacientes con enfermedad pulmonar obstructiva crónica
Patient compliance with inhaled medication therapy in chronic obstructive pulmonary disease
Visits
9131
J.L. Viejoa,*, P. Martín Escribanob, S. Romeroc, J.R. Rodríguez Suárezd, V. Sobradilloe, A. Valenciaf
a Servicio de Neumología. Hospital General Yagüe. Burgos
b Servicio de Neumología. Hospital 12 de Octubre. Madrid
c Servicio de Neumología. Hospital General de Alicante
d Servicio de Neumología. Hospital Xeral Santiago de Compostela
e Servicio de Neumología. Hospital de Cruces. Bilbao
f Servicio de Neumología. Hospital Carlos Haya. Málaga
This item has received
Article information
Objetivos

Evaluar el cumplimiento de la terapia inhalada en enfermos con enfermedad pulmonar obstructiva crónica, identificar los factores determinantes y proponer medidas correctoras para mejorar dicho cumplimiento.

Métodos

Estudio abierto observacional, de corte transversal, no comparativo, de estimación puntual y no aleatorio. Los inhaladores objeto del estudio fueron Serevent Accuhaler® y Flixotide Inhalador®. El cumplimiento se evaluó mediante cuatro métodos: a) diferencia del peso inicial y final para todos los dispositivos; b) por el contador de dosis del Accuhaler®; c) información proporcionada por el paciente mediante fichas diarias (por días y por aplicaciones), y d) por entrevista con el paciente mediante la prueba de Morinsky-Green. El cumplimiento se estratificó según los siguientes valores: bajo (<50%), medio (51-79%), alto (80- 119%) e “hipercumplimiento” (>\120%).

Resultados

Se incluyeron 72 pacientes con una media de edad de 65 años. El cumplimiento medido por peso de los dispositivos fue alto en el 77,1% de los pacientes, medio en el 11,5%, bajo en el 1,4% y un 10% fueron hipercumplidores. El cumplimiento alto para el Accuhaler® se midió por el peso del dispositivo y por contador de dosis, siendo de un 75 y un 83,3% de los pacientes, respectivamente. Según la ficha diaria del paciente, el cumplimiento alto por aplicaciones fue del 98,8%, y por días del 98,3%. Según la prueba de Morinsky- Green el cumplimiento fue alto en el 87,9% de los pacientes.

Conclusiones

Los valores de cumplimiento obtenidos por los diferentes métodos de valoración fueron buenos. Existe una tendencia al buen cumplimiento en pacientes que vivían en familia, con un nivel socioeconómico alto, con regímenes terapéuticos sencillos y con un buen conocimiento de la enfermedad y del inhalador. El seguimiento estrecho del paciente y la buena comunicación con el médico han mejorado los resultados de cumplimiento. No obstante, serán necesarios estudios posteriores para contrastar los resultados obtenidos.

Palabras clave:
Cumplimiento
Enfermedad pulmonar obstructiva crónica (EPOC)
Administración inhalatoria
Objectives

To evaluate patient compliance with inhaled medication therapy in chronic obstructive pulmonary disease (COPD), to identify determining factors and to propose corrective measures to improve compliance.

Methods

This was an open, observational, cross-sectional, non-comparative, single-measurement, non-random study. The inhalers were the Serevent Accuhaler®, the Serevent Inhalador® and the Flixotide Inhaler®. Compliance was measured in four ways: a) difference in weight at the beginning and end of the study for all devices; b) dose counter reading for the Accuhaler®; c) information from patient diaries (by days and by applications); and d) information from patient interviews using the Morinsky-Green Test. Compliance was rated as follows: poor: <50%, fair 51%-79%, good 80%-119%, or “hypercompliant” >\120%.

Results

Seventy-two patients (mean age 65 years) were enrolled. Compliance measured by weight was good in 77.1%, fair in 11.5%, poor in 1.4% and hypercompliant in 10%. Compliance was good for the Accuhaler® according to both weight (75%) and counted doses (83.3%). According to patient diaries, compliance was good when assessed by applications (98.8%) and by days (98.3%). According to the Morinksky-Green test, compliance was good for 87.9%.

Conclusions

Compliance was good as assessed by the methods used in this study. Patients who live in families, who enjoy a high socioeconomic level, have simple therapeutic regimens and have a good understanding of their disease and inhaler tend to have good compliance. Careful patient follow-up and good patient-physician communication has improved compliance. However, follow-up studies are needed to check these results.

Key words:
Compliance
COPD
Inhaled administration
Full text is only aviable in PDF
Bibliografía
[1.]
J. Murphy, G. Coster.
Issues in patient compliance.
Drugs, 54 (1997), pp. 767-800
[2.]
R. Mateos, M. Camacho Álvarez.
Causas y consecuencias del incumplimiento de la prescripción médica.
Med Clin (Barc), 10 (1996), pp. 276-277
[3.]
C.M. Bosley, D.T. Parry, G.M. Cochrane.
Patient compliance with inhaled medication Does combining beta agonist with corticosteroids improve compliance?.
Eur Respir J, 7 (1994), pp. 504-509
[4.]
B. Haynes, K.A. McKibbon, R. Kanani.
Systematic review of randomzied trials of intervention to assist patient to follow prescriptions for medications.
Lancet, 248 (1996), pp. 383-386
[5.]
P.N.E. James, J.B. Anderson, J.G. Prior.
Patterns of drugs taking in patients with chronic airflow obstruction.
Postgrad Med J, 61 (1985), pp. 7-10
[6.]
E. Dompleing.
Treatment with inhaled steroids in asthma and chronic bronchitis; long term compliance and inhaler technique.
Fam Pract, 9 (1992), pp. 161-166
[7.]
J. Turner, E. Wright, L. Mendella, N. Anthonisen, e IPPB study group.
Predictors of patient adherence to a long term home nebulizer therapy for COPD.
Chest, 108 (1995), pp. 394-400
[8.]
C.S. Rand, para el Lung Heralth Study Research Group.
Long term metered dose inhaler adherence in a clinical trial.
Am J Respir Crit Care Med, 152 (1995), pp. 580-588
[9.]
C.M. Bosley, Z.M. Corden, P.J. Rees, G.M. Cochrane.
Physological factors associated with use for home nebulized therapy for COPD.
Eur Respir J, 6 (1996), pp. 2346-2350
[10.]
T. Montemayor, I. Alfejame, C. Escudero, J. Morera, L. Sánchez.
Diagnóstico y tratamiento de la enfermedad pulmonar obstructiva crónica.
Recomendaciones SEPAR. Barcelona: Ediciones Doyma, (1998), pp. 115-146
[11.]
D.E. Moriski, L.W. Green, M. Levine.
Concurrent and predictive of a self reported measure of medication adherence.
Med Care, 24 (1986), pp. 67-74
[12.]
J. Van der Palen, J.J. Klein, M.M. Roves.
Compliance with inhaled medication and self-treatment guidelines following a self-management programme in adult asthmatics.
Eur Respir J, 10 (1997), pp. 652-657
[13.]
M.E. Hyland.
Types of non compliance.
Eur Respir Rev, 8 (1998), pp. 255-259
[14.]
P.W. Jone.
Heath status, quality of life and compliance.
Eur Respir Rev, 8 (1998), pp. 243-246
[15.]
J.L. Viejo.
Cumplimiento de la terapia inhalada en la EPOC.
Nuevos problemas en neumología,
[16.]
J.T. Marino.
Enhancing patient compliance in asthma management.
Chest, 10 (1996), pp. 862
[17.]
S. Keller.
Implications of the stages of change Medel for medication compliance.
Eur Respir Rev, 8 (1998), pp. 260-266
Copyright © 2000. Sociedad Española de Neumología y Cirugía Torácica
Archivos de Bronconeumología
Article options