Journal Information
Vol. 15. Issue 3.
Pages 132-136 (July - September 1979)
Share
Share
Download PDF
More article options
Vol. 15. Issue 3.
Pages 132-136 (July - September 1979)
Full text access
Valoracion de clenbuterol en la enfermedad pulmonar obstructiva cronica descompensada
Evaluation of clenbuterol in decompesated chronic obstructive pulmonary disease
Visits
6822
M. de Frutos Herranz, A. Montón Rodríguez, R. Giral Sanz, J.M. Ayuela Azcárate, L. Nuño Gil
Servicio de Cuidados Intensivos de la Residencia Sanitaria General Yogue. Burgos
This item has received
Article information
Abstract
Bibliography
Download PDF
Statistics
Resumen

En 10 pacientes diagnosticados de enfermedad pulmonar obstructiva crónica (E.P.O.C.), en fase de descompensación y sometidos a ventilación mecánica con respirador Bird Mark-8 a presión límite fija, se ha valorado la eficacia de un simpaticomimético |32 preferencial, clenbuterol. Según los parámetros controlados, aumenta el volumen minuto respiratorio, valorado como índice de broncodilatación, se reducen de forma poco valorable las presiones arteriales sistémica y pulmonar, mientras que el efecto β1, investigado según las modificaciones de la frecuencia cardiaca y de un índice de contractilidad, la fase de preeyección (F.P.E.), debe considerarse muy escaso. Los controles efectuados sobre la variación de la admisión venosa pulmonar (Qva/Qt y sobre el cociente ventilación/perfusión (VA/Q) informan de que las alteraciones de contacto entre los flujos aéreo y sanguíneo pulmonares, previamente existentes en los enfermos afectos de esta patología, no se agravan.

Summary

In the patients diagnosed as having chronic obstructive pulmonary disease in phase of decompensation and submitted to mechanical ventilation with a Bird Mark-8 respirator at fixed pressure limit, the authors have evaluated the efficacy of a preferential β2 sympathomimetic, clenbuterol. According to the parameters controlled, the respiratory volume per minute increased, evaluated as an índex of bronchodilatation, the systemic and pulmonary arterial pressures were reduced in a way only slightly evaluatable, while the effect (f, investigated, according to the modifícations of cardiac frequency and of an índex of contractility, the phase of pre-ejection, must be considered to be very scarce. Controls of variation of the pulmonary venous admission (Qva/Qt) and on the quotient ventilation/perfusion (VA/Q) indicated that the alterations of contact between air flows and pulmonary blood flows, that existed previously in patients suffering from this pathology, were not aggravated.

Full text is only aviable in PDF
Bibliografía
[1.]
L. Reid.
Measurement of the bronchial mucous gland layen a diagnostic yardistick in chronic bronchitis.
Thorax, 15 (1960), pp. 32
[2.]
T. Takizawa, W.M. Thurlbeck.
Muscle and mucous gland size in the major bronchi of patients with chronic bronchitis, asthma and asthmatic bronchitis.
Amer. Rev. Resp. Dis., 104 (1971), pp. 331
[3.]
S. Hossain, B.E. Heard.
Hyperplasia of bronchial muscle in chronic bronchitis.
J. Pathol., 10 (1970), pp. 171
[4.]
S.M. Ayres, S.J. Griesbach, F. Reimold, R.G. Evans.
Bronchial component in chronic obstructive lung disease.
Amer. J. Med., 57 (1974), pp. 183
[5.]
J. Castillo, M. Diaz.
Estudio por el método doble ciego de un broncodilatador betaestimulante: hexoprenalina.
Arch. Bronconeumol., 12 (1976), pp. 146
[6.]
A.M. Lands, A. Arnold, J.P. Mcauliff, F.P. Ludena, T.J. Brown.
Difierentiation of receptor sistems activated by sympathomimetic amines.
Nature, 214 (1967), pp. 597
[7.]
B.F. Scherreiner, G.W. Murphy, D.H. James, P.N. Yu.
Effects of isopr ternol on the pulmonary blood volume in patients with valvular heart disease and primary myocardial disease.
Circulation, 37 (1968), pp. 220
[8.]
J.S. Legge, J. Gaddie, K.N.V. Palmer.
Comparison of two oral selective adrenergic stimulant drugs in bronchial asthma.
Brit. Med. J., 1 (1971), pp. 637
[9.]
L. Lho, R.F. Seed, M.K. Sykes.
Cardiorrespiratory effects of intravenous isoprenaHne and salbutamol in dogs.
Br. J. Pharmacol., 43 (1971), pp. 624
[10.]
M.D.E. Frutos.
Comportamiento de broncodilatadores en broncópatas descompensados sometidos a ventilación controlada.
(1977),
[11.]
A.M. Weissler, W.S. Harris, C.D. Schoenfeld.
Bedside technics for the evaluation of ventricular function in man.
Amer. J. Cardiol, 23 (1969), pp. 57
[12.]
S.M. Bergreen.
The oxigen deficit of arterial blood caused by non-ventilating parts of the lung.
Acta Physiol. Scand., 4 (1942), pp. 1
[13.]
R.L. Riley, A. Cournand.
Ideal alveolar air and the analysis of ventilation perfusión ratios in the lungs.
J. Appl. Physiol., 1 (1949), pp. 825
[14.]
J.B. West.
Fisiología respiratoria.
58, Panamericana., (1976),
[15.]
R. Schindl, E. Irnberger, L. Pringdinger.
Kurz und langzeitvergleich adrenerger bronchospasmolytika.
Med. Welt., 26 (1975), pp. 834
[16.]
S.R. O’Donnell.
NAB 365 is it a selectiveadrenoceptor agonist?.
Clin. Exper. Pharmacol. Physiol., 2 (1976), pp. 412
[17.]
E. Hufnagel.
Ergebnisse mit einem neuen broncholytikum. Einfluss auf hertzfrequenz blutdruck und EKG.
Arztl. Prax., 26 (1974), pp. 1350
[18.]
D. Taeger.
Revisión del broncoespasmolítico NAB 365 en una prueba doble ciega.
Med. Klin., 70 (1975), pp. 1052
[19.]
H. Kessler.
Erfahrungen mit clenbuterol-tabletten bei der langzeitpríufung.
Fortsch. Med., 93 (1975), pp. 1686
[20.]
R.M.M. Fordham, L. Resnekov.
Arterial hypoxaemia. A side-effect of intravenous isoprenaline used after cardiac surgery.
Thorax, 23 (1968), pp. 19
[21.]
C.K. Dashe, R.A. Ponto, C.M. Ganapes, C.V. Drage, R.S. Kronenberg.
The distribution of nebulized isoproterenol and its effects on regional ventilation and perfusión.
Amer. Rev. Resp. Dis., 110 (1974), pp. 293
[22.]
J.C. Mithoefer, J.F.H. Keighley, W.R. Cook.
The AaDO2 and venous admixture at varying inspired oxygen concentrations in chronic obstructive pulmonary disease.
Crit. Care. Med., 6 (1978), pp. 131
[23.]
R. Pelsin, G. Bellaga.
Perfomances des systémes de dilution air-oxygène de quelques apareils de ventilation artificielle.
Bull. Physio-path. Resp., 9 (1973), pp. 1163
[24.]
J. Andonegui, A. Pardo, J.L. Casalduero.
Estudio comparativo de la concentración de oxygeno liberado por respiradores Benett PR-2 y Bird Mark-8.
Rev. Esp. Anest. Rean., 22 (1976), pp. 873
[25.]
R.H. Goldman, B. Braniff, D.C. Harrison, H.J. Spivack.
The use of central venous oxygen saturation measurements in a coronary care unit.
Ann. Intern. Med., 68 (1968), pp. 1280
[26.]
M.N. Scheinman, M.A. Brown, E. Rappaport.
Critical assessment of use of central venous oxigen saturation as a mirror of mixed venous oxigen in severely ill patients.
Circulation, 41 (1970), pp. 641
[27.]
J. Cavanilles.
Reliability of central venous blood for calculating pulmonary shunts.
Fed. Proc., 31 (1972), pp. 348
[28.]
J.R. Oncins, M. Planas, F.J. Avila, J. Remon, J.M. Cavanilles.
Correlación entre la saturación de oxígeno en la sangre de la aurícula derecha y en sangre de la arteria pulmonar.
Rev. Clin. Esp., 140 (1976), pp. 125
Copyright © 1979. Sociedad Española de Neumología y Cirugía Torácica
Archivos de Bronconeumología
Article options
Tools

Are you a health professional able to prescribe or dispense drugs?